Laminar Sheet Physics & The Coanda Effect Over Waterfall Lips
An architectural sheetfall waterfall must produce a glassy, unbroken, translucent curtain of water that projects gracefully away from the feature wall. If internal turbulence is unmitigated, the water sheet ruptures prematurely into ragged spray strings, causing erratic splashing, aesthetic failure, and acoustic harshness.
Achieving a pristine sheer descent waterfall requires mastering the Coanda effect—the tendency of fluid jets to adhere to convex surfaces. Fludio precision-machines the waterfall discharge weir lip with a razor-sharp 45° downward chamfer and dual air-break relief grooves. This prevents water from clinging back along the wall cladding, ensuring clean release into the basin below.
Internal Flow Baffles & Hydraulic Calming Chambers
When pressurized water enters a weir trough from bottom or rear pipe inlets, it carries high localized momentum and chaotic eddy currents. To transform this turbulent influx into a placid, uniform sheet across weir spans up to 3000 mm, Fludio incorporates a proprietary dual-chamber internal baffle assembly.
The primary expansion chamber absorbs hydraulic kinetic energy and distributes flow across internal perforated diffuser plates. Water then cascades over an internal weir wall into the secondary calming chamber before spilling over the exterior lip at non-turbulent Reynolds numbers (( Re < 1500 )).
Flow Rate Sizing: Liters Per Minute Per Linear Meter
Proper pump sizing is paramount to waterfall sheet performance. If the flow rate is too low, the sheet narrows inward (necking) and ruptures halfway down. If flow is excessive, turbulent surging causes loud splashing.
For architectural sheer descents with vertical drops up to 1.5 meters, Fludio specifies:
For monumental drops exceeding 2.5 meters or outdoor windy rooftop terraces, flow is increased to 160–220 LPM/meter with extended 150 mm projection weir lips.
Acoustic Tuning & Indoor Corporate Decibel Control
In corporate atriums, wellness retreats, and hotel lobbies, the acoustic signature of falling water must enhance relaxation without overpowering normal speech. Sound level is dictated by impact velocity:
By installing submerged acoustic deceleration baffles and pebble-covered anti-splash collection grates in the lower pool, decibel levels can be attenuated from an aggressive 75 dBA down to a soothing, biophilic 52 dBA white-noise background.
| Model | Weir Width (mm) | Lip Projection | Recommended Flow (LPM) | Inlet Diameter | Max Drop Height |
|---|---|---|---|---|---|
| FL-WF-0600 | 600 mm | 75 mm / 150 mm | 60 – 90 LPM | 1x 1.25" BSP Bottom/Rear | 1.5 m (5.0 ft) |
| FL-WF-0900 | 900 mm | 75 mm / 150 mm | 90 – 140 LPM | 1x 1.5" BSP Bottom/Rear | 2.0 m (6.6 ft) |
| FL-WF-1200 | 1200 mm | 75 mm / 150 mm | 120 – 180 LPM | 2x 1.5" BSP Dual Feed | 2.5 m (8.2 ft) |
| FL-WF-1500 | 1500 mm | 100 mm / 200 mm | 160 – 240 LPM | 2x 1.5" BSP Dual Feed | 3.0 m (9.8 ft) |
| FL-WF-2000 | 2000 mm | 100 mm / 200 mm | 220 – 320 LPM | 3x 1.5" BSP Triple Feed | 3.5 m (11.5 ft) |